NEO® MICRO AGGLOMERATED CORK STOPPERS

With micro-agglomerated NEO® stoppers, consumers can appreciate the look and feel of natural cork, which demonstrates our ongoing commitment to the quality and sustainability of the cork stopper value chain.

After punching the natural cork stoppers, cork shavings are carefully selected and processed.

There are three types of micro cork stoppers: NEO SELECT®, NEO PRESTIGE® and NEO PLUS®.

Through a series of mechanical operations, the material is reduced to uniformly-sized particles. These particles are carefully treated, through moulding – a process for producing agglomerated bodies – and cutting edge M.A.SILVA technologies.

DYNAVOX®

Sterilisation and vaporisation of raw materials

MASZONE®

Sterilisation and elimination of microorganisms

NEOTECH®

Sterilisation and vaporisation of granules

We can supply FSC® certified products (FSC – C009204) upon request.

Search for the NEO® stopper that best meets your needs.

NEO SELECT® CORK STOPPERS

NEO SELECT®
Technical Sheet

TECHNICAL SPECIFICATIONS

STANDARD SIZES: 49x24mm | 49×25 mm

TECHNICAL SPECIFICATIONS:
NEO SELECT® micro-agglomerate cork stoppers, which incorporate more ecological components throughout their 100% vertical production process. Technical stoppers with the benefits of an ecological stopper and the feel of a natural stopper. The best choice for those who decide bearing in mind the planet and the quality of the wine to be preserved.

PHYSICAL-MECHANICAL:
Lenght: X ± 0,5 mm
Diameter: X ± 0,3 mm
Dimensional Recovery: ≥ 96%
Moisture: 3% < HR < 7%
Specific weight: +/- 40 kg/m3
Boiling water resistence: No desintegration
Sealing capacity: No leaks at 2 bar (20°C)
Chamfer: 2,5 mm
Granules size: 0,5 mm – 1 mm
Microspheres: No use
Bonding agent: Plant-based polyol

PHYSICAL-CHEMICAL:
Stopper Extraction Forces: 15daN<Fe<45daN
OIR (1) 6 months: 0,89 mg
OTR (1) 12 months: 1,00 mg
OTR (1) Per year, after 12 months: 0,05 mg
(1) OIR – Oxygen Initial Release. OTR – Oxygen Transfer Rate. Results obtained by chemiluminescence with CETIE bottles.
TCA (2): < 0,5 ng/L
(2) Quantification limit of 0,5 ng/L. Analysis performed in accordance to ISO 20752.
PRODUCTION:
Process: Moulding
Branding: Ink, Laser and Fire

STORAGE:
Use no later than (3): 6 months
(3) As a good practice. the product should be used according to the FIFO methodology and as soon as possible, keeping the bags closed.
Moisture in storage: 40% – 70% RH
Storage temperature: 15ºC – 20ºC | 59ºF – 68ºF
Storage place: Store the stoppers in a clean, well-ventilated and odor-free place, away from products containing chlorine.

NEO PRESTIGE® CORK STOPPERS

NEO® PRESTIGE
Technical Sheet

TECHNICAL SPECIFICATIONS

STANDARD SIZES: 38×24 mm | 44×24 mm | 47x24mm | 49×24 mm

PHYSICAL-MECHANICAL:
Lenght: X ± 0,5 mm
Diameter: X ± 0,3 mm
Dimensional Recovery: > 96%
Moisture: 3% < HR < 7%
Specific weight: +/- 40 kg/m3
Boiling water resistence: No desintegration
Sealing capacity: No leaks at 2 bar (20°C)
Chamfer: 2,5 mm
Granules size: 0,5 mm – 1 mm

PHYSICAL-CHEMICAL:
Stopper Extraction Forces: 15daN<Fe<45daN
OIR (1) 6 months: 0,91 mg
OTR (1) 12 months: 1,02 mg
OTR (1) Per year, after 12 months: 0,05 mg
(1) Results obtained by chemiluminescence with CETIE bottles.
TCA (2): < 0,5 ng/L
(2) Quantification limit of 0,5 ng/L. Analysis performed in accordance to ISO 20752.
PRODUCTION:
Process: Moulding
Branding: Ink, Laser and Fire

STORAGE:
Use no later than (3): 6 months
(3) As a good practice. the product should be used according to the FIFO methodology and as soon as possible, keeping the bags closed.
Moisture in storage: 40% – 70% RH
Storage temperature: 15ºC – 20ºC | 59ºF – 68ºF
Storage place: Store the stoppers in a clean, well-ventilated and odor-free place, away from products containing chlorine.

NEO PLUS® CORK STOPPERS

NEO PLUS®
Technical Sheet

TECHNICAL SPECIFICATIONS

STANDARD SIZES: 38×24 mm | 44×24 mm | 47x24mm

PHYSICAL-MECHANICAL:
Lenght: X ± 0,5 mm
Diameter: X ± 0,3 mm
Dimensional Recovery: > 96%
Moisture: 3% < HR < 7%
Specific weight: +/- 40 kg/m2
Boiling water resistence: No desintegration
Sealing capacity: No leaks at 2 bar (20°C)
Chamfer: 2,5 mm
Granules size: 0,5 mm – 2 mm

PHYSICAL-CHEMICAL:
Stopper Extraction Forces: 15daN<Fe<45daN
OIR (1) 6 months: 1,44 mg
OTR (1) 12 months: 1,62 mg
OTR (1) Per year, after 12 months: 0,10 mg
(1) Results obtained by chemiluminescence with CETIE bottles.
TCA (2): < 0,5 ng/L
(2) Quantification limit of 0,5 ng/L. Analysis performed in accordance to ISO 20752.
PRODUCTION:
Process: Moulding
Branding: Ink, Laser and Fire

STORAGE:
Use no later than (3): 5 months
(3) As a good practice. the product should be used according to the FIFO methodology and as soon as possible, keeping the bags closed.
Moisture in storage: 40% – 70% RH
Storage temperature: 15ºC – 20ºC | 59ºF – 68ºF
Storage place: Store the stoppers in a clean, well-ventilated and odor-free place, away from products containing chlorine.